Використання абсорбційних холодильних установок в системах утилізації теплоти високотемпературних теплотехнологічних агрегатів
| dc.contributor.author | Кошельнік О. В. | |
| dc.contributor.author | Кунденко М. П. | |
| dc.contributor.author | Пугачова Т. М. | |
| dc.contributor.author | Круглякова О. В. | |
| dc.contributor.author | Єгорова О. Ю. | |
| dc.contributor.author | Тарасенко О. М. | |
| dc.contributor.author | Руденко А. Ю. | |
| dc.contributor.author | Koshelnik Oleksandr V. | |
| dc.contributor.author | Kundenko Mykola P. | |
| dc.contributor.author | Pugachova Tetiana M. | |
| dc.contributor.author | Krugliakova Olga V. | |
| dc.contributor.author | Yegorova Olga Yu. | |
| dc.contributor.author | Tarasenko Oleksandr О. | |
| dc.contributor.author | Rudenko Andrii Yu. | |
| dc.date.accessioned | 2026-10-01T08:36:39Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Розглянуто питання підвищення енергоефективності скловарного виробництва в системах утилізації теплоти високотемпературних теплотехнологічних агрегатів. Запропоновано доповнювати системи випарного охолодження скловарних печей бромістолітієвими абсорбційними холодильними машинами, які забезпечують вироблення холоду за рахунок теплової енергії низькопотенційної пари. Мета. Розробка схеми утилізації енергетичного потенціалу низькопотенційної пари систем випарного охолодження високотемпературних теплотехнологічних агрегатів скловарного виробництва із застосуванням абсорбційних холодильних установок та подальшою оцінкою її ефективності. Методика. У дослідженні використано метод системного аналізу, який дозволяє розглядати об’єкт як єдину термодинамічну систему «скловарна піч–система випарного охолодження–абсорбційна холодильна машина– споживач холоду». Результати. Вибір конкретної утилізаційної схеми має враховувати технологічні потреби підприємства та визначатися за критерієм максимального економічного ефекту. Використання абсорбційних холодильних установок сприяє зниженню собівартості продукції та підвищенню загальної економічності технологічних процесів виробництва скломаси. Для оцінки ефективності запропонованої схеми доцільно застосовувати методи ексергетичних аналізу, а в якості критерію ефективності – ексергетичний коефіцієнт утилізації. Наукова новизна. Обґрунтовано доцільність застосування двоступеневих абсорбційних холодильних машин в системах утилізації теплоти скловарних печей, що дозволяє отримувати холод при мінімальних витратах електроенергії, використовуючи як джерело енергії низькотемпературну пару систем випарного охолодження. Практична значимість. Застосування двоступеневих абсорбційних бромістолітієвих холодильних машин у системах утилізації теплоти скловарних печах дозволяє знизити витрати охолоджуючої води, підвищити тепловий коефіцієнт та уникнути необхідності додаткового підвищення параметрів пари. Це зменшує вартість утилізаційної системи та забезпечує значний економічний ефект. | |
| dc.description.abstracteng | The issue of improving energy efficiency in glass-melting production within heat recovery systems of hightemperature thermal units has been considered. It is proposed to complement the evaporative cooling systems of glassmelting furnaces with lithium bromide absorption refrigeration machines, which provide cold production utilizing the thermal energy of low-potential steam. Purpose. Development of a scheme for the utilization of the energy potential of low‑grade steam from evaporative cooling systems of high‑temperature thermal process units in glass‑melting production, employing absorption refrigeration installations and followed by an assessment of their efficiency. Method. The study employs the method of system analysis, which makes it possible to consider the object as a single thermodynamic system: «glass-melting furnace–evaporative cooling system–absorption refrigeration machine–cold consumer». Results. The selection of a specific heat‑recovery scheme must take into account the technological requirements of the enterprise and be determined by the criterion of maximum economic effect. The application of absorption refrigeration units contributes to reducing product cost and improving the overall economic efficiency of glass‑melting technological processes. For evaluating the effectiveness of the proposed scheme, it is advisable to apply methods of exergy analysis, with the exergy utilization coefficient adopted as the efficiency criterion. Scientific novelty. The feasibility of applying two-stage absorption refrigeration machines in waste heat recovery systems of glass-melting furnaces has been substantiated, which makes it possible to produce cooling with minimal electricity consumption by using low-temperature steam from evaporative cooling systems as the energy source. Practical importance. The application of two-stage lithium bromide absorption refrigeration machines in heat recovery systems of glass-melting furnaces makes it possible to reduce cooling water consumption, increase the thermal coefficient, and avoid the need for additional steam parameter enhancement. This lowers the cost of the recovery system and provides a significant economic benefit. | |
| dc.identifier.citation | Використання абсорбційних холодильних установок в системах утилізації теплоти високотемпературних теплотехнологічних агрегатів = Ensuring the operational stability of thermal power plant units under variable loads in the context of instability of ukraine’s power system / О. В. Кошельнік, М. П. Кунденко, Т. М. Пугачова, О. В. Круглякова, О. Ю. Єгорова, О. М. Тарасенко, А. Ю. Руденко // Зб. наук. пр. НУК. – Миколаїв : Гельветика, 2026. – № 1 (504), т. 1. – С. 164–170. | |
| dc.identifier.govdoc | https://doi.org/10.15589/znp2026.1(503).1.19 | |
| dc.identifier.issn | 2311-3405 (Print) | |
| dc.identifier.issn | 2313-0415 (Online) | |
| dc.identifier.uri | https://eir.nuos.edu.ua/handle/123456789/13727 | |
| dc.language.iso | uk | |
| dc.relation.ispartofseries | 621.574.013-932 | |
| dc.subject | система утилізації теплоти | |
| dc.subject | абсорбційна холодильна установка | |
| dc.subject | отримання холоду | |
| dc.subject | термодинамічний аналіз | |
| dc.subject | підвищення ефективності | |
| dc.subject | Heat recovery system | |
| dc.subject | absorption refrigeration unit | |
| dc.subject | cold production | |
| dc.subject | thermodynamic analysis | |
| dc.subject | efficiency improvement | |
| dc.title | Використання абсорбційних холодильних установок в системах утилізації теплоти високотемпературних теплотехнологічних агрегатів | |
| dc.title.alternative | Ensuring the operational stability of thermal power plant units under variable loads in the context of instability of ukraine’s power system | |
| dc.type | Стаття |