Heat transfer during refrigerant boiling in smooth horizontal tubes of marine low-temperature air coolers
| dc.contributor.author | Lytosh Olena V. | |
| dc.contributor.author | Prylutskyi Anatolii A. | |
| dc.contributor.author | Литош О. В. | |
| dc.contributor.author | Прилуцький A. A. | |
| dc.date.accessioned | 2025-09-19T08:48:56Z | |
| dc.date.issued | 2025 | |
| dc.description | Lytosh, O. V. Heat transfer during refrigerant boiling in smooth horizontal tubes of marine low-temperature air coolers = Теплообмін при кипінні холодоагента в гладких горизонтальних трубах суднових низкотемпературних повітроохолоджувачів / O. V. Lytosh, A. A. Prylutskyi // Зб. наук. пр. НУК. – Миколаїв : Гельветика, 2025. – № 2 (500). – С. 88–94. | |
| dc.description.abstract | Наведені результати експеримента по призначенню коефіцієнта тепловіддачі при кипінні холодоагенту у горизонтальній трубі повітроохолоджувача при температурах –18 і –37 ºС, по яким підібрани формули для його розрахунку. Мета. Отримання дослідних даних з тепловіддачі при кипінні холодоагенту в горизонтальній трубі, включеної до схеми холодильної машини, при температурах до –40 ºС та на підставі цих даних обґрунтовано підібрати розрахункові залежності для визначення коефіцієнта тепловіддачі. Методика. При проектуванні охолоджувачів повітря (ПО) систем рефрижерації важливим є правильний вибір розрахункових залежностей для визначення коефіцієнта тепловіддачі. Аналіз рівнянь, що описують мін у ПО з внутрішньотрубним кипінням холодоагентів, вказує на існування протиріч у їх виборі, а обчислені за різними рівняннями значення середніх коефіцієнтів тепловіддачі мають значну розбіжність (до 75 %). У відомих літературних джерелах відсутні дані щодо експериментальних коефіцієнтів тепловіддачі, які могли б служити критерієм обґрунтованого вибору розрахункових залежностей для визначення коефіцієнтів тепловіддачі при температурі кипіння до –40 ºС. Значення коефіцієнта тепловіддачі залежить не тількі від режимних параметрів, а й від наявності у холодоагенті олії, і навіть інших чинників. При дослідженні процесів тепловіддачі до холодоагенту, що кипить усередині труб ПО, як опитний випарник зазвичай застосовували горизонтальну трубу з навитим на неї електронагрівачем. Результати. Отримано рівняння та залежності для розрахунку тепловіддачі при кипінні холодоагенту всередині гладких горизонтальних мідних труб для зон розшарованого та хвильового режимів течії, характерних для умов роботи низькотемпературних охолоджувачів повітря. Наукова новизна. В результаті досліджень отримані дослідні дані щодо коефіцієнтів тепловіддачі при внутрішньотрубному низькотемпературному (–37 і –18 ºС) кипінні холодоагенту, підібрано рівняння та запропоновано напівемпіричну залежність, що враховує вплив олії на тепловіддачу при кипінні. Запропоновані рівняння рекомендовані до застосування при проектуванні низькотемпературних охолоджувачів повітря. Практична значимість. Запропоновані авторами розрахункові та дослідні співвідношення були використані при розробці герметичних холодильних машин для провізійних комор. | |
| dc.description.abstract1 | The results of experiment for definition of heart transfer coefficient during refrigerant boiling in the horizontal tube of air coolers on the evaporating temperatures of –18 and –37 ºC were conducted, which on selected formulas for its calculations. Purpose. To obtain experimental data on heat transfer during refrigerant boiling in a horizontal tube integrated into a refrigeration system, at temperatures as low as –40 °C, and to use these data to reasonably select calculation correlations for determining the heat transfer coefficient. Method. In the design of air coolers (AC) for refrigeration systems, the accurate selection of calculation correlations for determining the heat transfer coefficient is crucial. An analysis of the equations describing heat transfer in ACs with in-tube boiling of refrigerants reveals contradictions in the choice of these correlations. Moreover, the average heat transfer coefficients calculated using different equations can vary significantly – by up to 75 %. The available literature lacks experimental data on heat transfer coefficients that could serve as a reliable benchmark for selecting appropriate calculation correlations for determining heat transfer coefficients at boiling temperatures down to –40 °C. The value of the heat transfer coefficient depends not only on operating parameters but also on the presence of oil in the refrigerant, as well as other influencing factors. In studies of heat transfer to refrigerants boiling inside air cooler tubes, a horizontal tube wrapped with an electric heater has typically been used as a test evaporator. Results. Equations and dependencies are obtained for calculating heat transfer during boiling of a refrigerant inside smooth horizontal copper pipes for zones of stratified and wave flow regimes, typical for the operating conditions of low-temperature air coolers. Scientific novelty. As a result of research experimental data were obtained for heat transfer coefficients during in-tube refrigerant boiling at low temperatures (–37 °C and –18 °C). Based on the results, appropriate equations were selected, and a semi-empirical correlation accounting for the influence of oil on boiling heat transfer was proposed. The proposed equations are recommended for use in the design of low-temperature air coolers. Practical importance. The proposed empirical and experimental correlations developed by the authors were applied in the design of hermetic refrigeration units for provision storerooms. | |
| dc.identifier.issn | 2311-3405 (Print) | |
| dc.identifier.issn | 2313-0415 (Online) | |
| dc.identifier.uri | https://eir.nuos.edu.ua/handle/123456789/11231 | |
| dc.language.iso | en | |
| dc.relation.ispartofseries | УДК; 621.51:628.84 | |
| dc.subject | heart transfer | |
| dc.subject | refrigerant boiling | |
| dc.subject | heart transfer coefficient | |
| dc.subject | теплообмін | |
| dc.subject | кипіння холодоагенту | |
| dc.subject | коефіцієнт тепловіддачі | |
| dc.title | Heat transfer during refrigerant boiling in smooth horizontal tubes of marine low-temperature air coolers | |
| dc.title.alternative | Теплообмін при кипінні холодоагента в гладких горизонтальних трубах суднових низкотемпературних повітроохолоджувачів | |
| dc.type | Article |
Файли
Контейнер файлів
1 - 1 з 1
Вантажиться...
- Назва:
- Lytosh.pdf
- Розмір:
- 940.81 KB
- Формат:
- Adobe Portable Document Format
Ліцензійна угода
1 - 1 з 1
Вантажиться...
- Назва:
- license.txt
- Розмір:
- 4.38 KB
- Формат:
- Item-specific license agreed upon to submission
- Опис: