| dc.date.issued | 2025 | |
| dc.description | Kochmarskii, V. Z. Water stabilization in water supply circulation systems = Стабілізація води в системах оборотного водопостачання / V. Z. Kochmarskii, O. P. Kostyuk, V. V. Kuba // Зб. наук. пр. НУК. – Миколаїв : Гельветика, 2025. – № 3 (501). – С. 97–102. | |
| dc.description.abstract | Метою даної роботи є розробка алгоритму реагентної стабілізації води в системах оборотного водопостачання (СОВП) для запобігання карбонатним відкладенням на граничних поверхнях та теплообміну, який базується на фізико-хімічній моделі карбонатної водної системи (КВС) і дозволяє визначати дозу реагентів на основі даних штатного визначення параметрів оборотної води (ОВ) та режиму роботи СОВП. Такий підхід дозволяє уникати передозування реагентів та скидання надлишкової ОВ у навколишнє середовище, а якщо СОВП є оборотною системою охолодження (ОСО) теплових та атомних електростанцій, то дозволяє уникати викидів надлишкових продуктів згоряння палива та зниження коефіцієнта корисної дії станції внаслідок відкладень. Методи. Відомо, що карбонат кальцію є основним компонентом низькотемпературних відкладень [1, с. 384]. З огляду на це, в статті розглядається гідрокарбонатна підсистема оборотної води, стан якої описується стаціонарною фізико-хімічною моделлю якості води, яка формулюється на основі: 1. Водно-сольового балансу водного середовища з урахуванням змін його обсягу. 2. Рівнянь паралельно-послідовних реакцій, що відображають перетворення в оборотній воді. 3. Припущення про форму кінетичних рівнянь, що описують кристалізацію карбонату кальцію, а також обмін CO2 між атмосферою та водним середовищем. 4. Закону збереження загальної кількості карбонатів. 5. Умови електричної нейтральності водного середовища. 6. Врахування істотної різниці між швидкостями реакцій в гідрокарбонатній системі (ГКС) відносно одна одної та часом обороту води в системі. Результати. Сформульовано кінетичні рівняння для компонентів, які є нейтральними щодо перетворень в ОВ; ми будемо називати їх трасерами, та тих, які зазнають змін в результаті фізико-хімічних реакцій в ОВ; ми будемо називати їх накипінами. Відкладення виникають в результаті процесів взаємного перетворення компонентів ГКС в ОВ, тому формулюється кінетичне рівняння для суми карбонатів в ОВ, яке не має обмежень щодо постійності об’єму ОСО і враховує процеси утворення твердого CaCO3 та дегазації CO2 у градирнях. Для стаціонарної роботи СОВП кінетичне рівняння для суми карбонатів перетворюється на рівняння для швидкості виділення CaCO3, яке враховує зміну концентрації гідрокарбонатних іонів і дегазацію CO2. Це рівняння дозволяє оцінити вплив на швидкість осадження CaCO3 дозування сірчаної кислоти у воду підживлення і визначити дозу кислоти, достатню для мінімізації відкладень CaCO3. Визначається концентрація гідрокарбонатних іонів і іонів Ca2+ у ОВ і підживлюваній воді, яка мінімізує швидкість осадження CaCO3 при заданій дозі кислоти. Практична цінність. Рівняння для швидкості виділення CaCO3, яке враховує зміни концентрації гідрокарбонатних іонів і дегазацію CO2 в градирнях, логічно відображає результати заходів щодо стабілізації оборотної води кислотою, і дозволяє отримати концентрацію Ca2+ в оборотній і та підживлюючій водах, які мінімізують відкладення CaCO3, а також визначити частку підживлюваної води, яку слід обробляти вапном, щоб мінімізувати відкладення, уникаючи при цьому передозування реагентів та шкоди навколишньому середовищу. Більше того, отримані рівняння дозволяють, на основі оперативних даних про якість оборотної води, контролювати ефективність заходів стабілізації та своєчасно їх коригувати. | |
| dc.description.abstract1 | The aim of this work is to develop an algorithm for reagent stabilization of water in closed-loop water supply systems (CWSS) to prevent carbonate deposits on boundary surfaces and heat exchange, which is based on a physicochemical model of a carbonate water system (CWS) and allows determining the dose of reagents based on data from routine determination of recycled water (RW) parameters and CWSS operating mode. This approach avoids overdosage of reagents and discharge of excess RW into the environment, and if the RWSS is a recirculating cooling system (RCS) of thermal and nuclear power plants, it avoids emissions of excess fuel combustion products and a decrease in the efficiency of the plant due to deposits. Methods. It is known that calcium carbonate is the main component of low-temperature deposits [1, p. 384]. In view of this, the article considers the hydrocarbonate subsystem of circulating water, the state of which is described by a stationary physicochemical model of water quality, which is formulated on the basis of: 1. The water-salt balance of the aquatic environment, taking into account changes in its volume. 2. Equations of parallel-sequential reactions reflecting transformations in circulating water. 3. Assumptions about the form of kinetic equations describing the crystallization of calcium carbonate, as well as the exchange of CO2 between the atmosphere and the aquatic environment. 4. The law of conservation of the total amount of carbonates. 5. Conditions of electrical neutrality of the aquatic environment. 6. Taking into account the significant difference between the reaction rates in the hydrocarbonate system (HCS) relative to each other and the water turnover time in the system. Results. Kinetic equations have been formulated for components that are neutral with respect to transformations in the water environment; we will call them tracers, and those that undergo changes as a result of physicochemical reactions in the water environment; we will call them forming deposits. Deposits arise as a result of the processes of mutual transformation of HCS components in the cooling water, therefore, a kinetic equation is formulated for the sum of carbonates in the cooling water, which has no restrictions on the constancy of the RCS volume and takes into account the processes of solid CaCO3 formation and CO2 degassing in cooling towers. For steady-state operation of the RCS, the kinetic equation for the sum of carbonates is converted into an equation for the rate of CaCO3 release, which takes into account the change in the concentration of hydrocarbonate ions and CO2 degassing. This equation allows us to estimate the effect of sulfuric acid dosing in the makeup water on the CaCO3 precipitation rate and determine the acid dose sufficient to minimize CaCO3 deposits. The concentration of hydrocarbonate ions and Ca2+ ions in the cooling water and makeup water is determined, which minimizes the rate of CaCO3 precipitation at a given acid dose. Practical value. The equation for the rate of CaCO3 precipitation, which takes into account changes in the concentration of hydrocarbonate ions and CO2 degassing in cooling towers, logically reflects the results of measures to stabilize the circulating water with acid, and allows obtaining the concentration of Ca2+ in the circulating and feed water that minimizes CaCO3 deposition, as well as determining the proportion of feed water that should be treated with lime to minimize deposition, while avoiding overdose of reagents and damage to the environment. Moreover, the equations obtained allow, based on operational data on the quality of circulating water, to monitor the effectiveness of stabilization measures and adjust them in a timely manner. | |
| dc.identifier.issn | 2311-3405 (Print) | |
| dc.identifier.issn | 2313-0415 (Online) | |
| dc.identifier.uri | https://eir.nuos.edu.ua/handle/123456789/11479 | |
| dc.language.iso | en | |
| dc.relation.ispartofseries | УДК; 621.311.02 | |
| dc.subject | circulating water | |
| dc.subject | hydrocarbonate subsystem | |
| dc.subject | minimization of CaCO3 deposits | |
| dc.subject | overdose of reagents | |
| dc.subject | оборотна вода | |
| dc.subject | гідрокарбонатна підсистема | |
| dc.subject | мінімізація відкладень CaCO3 | |
| dc.subject | передозування реагентів | |
| dc.title | Water stabilization in water supply circulation systems | |
| dc.title.alternative | Стабілізація води в системах оборотного водопостачання | |
| dc.type | Article |
Файли
Контейнер файлів
1 - 1 з 1
Вантажиться...
- Назва:
- Kochmarskii.pdf
- Розмір:
- 493.92 KB
- Формат:
- Adobe Portable Document Format
Ліцензійна угода
1 - 1 з 1
Вантажиться...
- Назва:
- license.txt
- Розмір:
- 4.38 KB
- Формат:
- Item-specific license agreed upon to submission
- Опис: